Open-plan corporate office in Hyderabad with ceiling-mounted occupancy sensors controlling zoned LED lighting and HVAC diffusers
    Commercial Sensor Automation

    Automatic Sensor Solutions for Commercial Buildings in India

    Automate lighting, HVAC, washrooms, parking and building operations based on how your spaces are actually being used. LiveInSmart designs, installs, programs and integrates occupancy, motion, presence and daylight sensor systems with lighting controls and building-management platforms for commercial and institutional environments.

    Sensor Automation Across Commercial Spaces

    Corporate conference room with a ceiling presence sensor holding lights and HVAC on while people sit still during a video call
    Conference rooms — mmWave presence sensors hold lighting and HVAC on for seated, motionless occupants.
    LiveInSmart engineer installing a ceiling-mounted PIR motion sensor in a commercial office corridor
    Installation — ceiling PIR sensors commissioned and time-delay tuned by our engineers, not left on factory defaults.
    Commercial washroom with sensor taps and occupancy-controlled lighting and exhaust fans
    Smart washrooms — occupancy-linked lighting, exhaust interlock and sensor taps for water saving.
    Basement commercial parking with green and red bay indicators driven by ultrasonic parking sensors
    Parking automation — bay-level ultrasonic detection with guidance indicators and motion-based lighting.
    Shopping mall atrium with a glass facade where daylight sensors dim perimeter lighting during bright hours
    Daylight harvesting — perimeter and atrium fixtures dim automatically against measured lux levels.
    Facility manager reviewing occupancy and energy consumption dashboards for a commercial building on control-room screens
    Energy dashboards — occupancy and consumption data per floor, zone and asset for facility teams.
    LiveInSmart consultant reviewing a sensor layout drawing with facility and IT managers in a corporate meeting room
    Site survey — sensor placement, coverage and BMS integration mapped before a single quote is issued.

    What Are Automatic Sensor Solutions?

    Automatic sensor solutions use sensors to detect occupancy, motion, presence, daylight, temperature, humidity, water leakage and vehicle presence, and use that information to control lighting, HVAC, washroom equipment, parking systems, alarms and the building management system (BMS). A well-engineered system works in four steps — detection, decision, control and monitoring — so the building responds to real use rather than fixed schedules. LiveInSmart designs, supplies, installs, programs, integrates, commissions and maintains these systems for offices, hospitals, schools, hotels, warehouses and commercial buildings.

    Detection → Decision → Control → Monitoring → Optimization

    A sensor by itself does not create automation. A working system is sensor + controller + automation logic + lighting/HVAC/other equipment + BMS/IBMS + monitoring + commissioning + AMC. LiveInSmart works as a commercial sensor automation and building intelligence integrator across that whole chain, not as a sensor seller.

    • Detection — the right sensor, mounting height and coverage overlap for each space
    • Decision — time delays, lux setpoints, schedules and override rules
    • Control — relays, dimmable drivers, DALI-2/KNX and HVAC interfaces
    • Monitoring — BMS/IBMS integration or dashboards for the facility team
    • Optimization — re-tuning under AMC as the use of the building changes

    Don't Automate the Sensor. Automate the Outcome.

    Sensors on their own do nothing useful. The outcome — a meeting room that stays lit during a still presentation, a corridor that dims at night, an AHU that sets back on an empty floor — comes from engineering the decision and the control behind each sensor. Every LiveInSmart design starts from the outcome the facility team wants and works backwards to the sensor.

    Automate the outcome, not the sensor — how LiveInSmart maps detection to building response
    What the sensor detectsDecisionWhat the building doesWhat gets recorded
    Occupancy detected in a cabin or meeting roomSpace in useLighting to working scene, HVAC to comfort modeOccupied state and runtime
    Room empty beyond the programmed delaySpace vacantLighting off or dimmed, HVAC set backVacancy time and energy data
    Daylight rises at the glazed perimeterEnough natural lightPerimeter fixtures dim to hold target luxDimming level by zone
    Washroom occupiedHygiene cycle requiredLights and exhaust on, exhaust run-on after exitUsage count for housekeeping
    Vehicle in parking bayBay takenBay indicator changes, guidance display updatesBay utilisation
    Temperature or humidity outside set bandCondition alarmHVAC adjusts, alert raised to facility teamAlarm log with timestamp
    Water detected under a pantry or plant-room floorLeak eventAlert, and valve shut-off where designedIncident record

    Types of Sensors Used in Commercial Automation

    Most commercial buildings need four or five sensor types, not one. The table lists the sensors we specify and the mistakes we design around.

    Sensor types used in commercial automation and where each belongs
    SensorWhat it sensesTypical useWatch out for
    PIR motionMoving body heatCorridors, staircases, stores, washroom lobbiesMisses people sitting still
    Dual-technology occupancyPIR plus ultrasonic agreementOpen offices, classrooms, cabinsNeeds commissioning of both channels
    mmWave presenceMicro-motion such as breathingBoardrooms, focus rooms, cabins, hybrid meeting roomsCan see through thin partitions if not zoned
    Microwave / high-bayDoppler motion at long rangeWarehouses, basements, high ceilingsOver-detection through walls
    Daylight / luxLight level at the work planeGlazed perimeters, atriums, receptions, classroomsWrong lux setpoint causes complaints
    TemperatureAir or surface temperatureHVAC zones, server rooms, cold storesMounting near diffusers or sunlight
    HumidityRelative humidityStores, archives, plant rooms, clinical support areasCalibration drift over time
    CO₂ / air qualityCO₂, VOC or particulates where applicableMeeting rooms, classrooms, auditoriumsNeeds a ventilation strategy to act on
    Door / window contactOpen or closed stateHVAC interlock, after-hours alertsOnly useful if wired to a response
    Water leakWater on floor or trayPantries, plant rooms, server rooms, shaftsPlacement at the true low point
    Ultrasonic parkingVehicle in bayBasement and multi-level parkingBay geometry and ceiling services
    People / footfall countingAnonymous entry and exit counts where applicableLobbies, retail, canteens, librariesPrivacy design and aggregation

    Motion vs Occupancy vs Presence Sensors

    These terms are often used interchangeably, which is why so many projects end with lights switching off on seated people. They are different tools.

    Motion vs occupancy vs presence sensors
    Motion sensorOccupancy sensorPresence sensor
    DetectsWalking movementMovement with a hold-on delay, often dual technologyFine movement including a still, seated person
    Best forTransit spacesGeneral offices and classroomsRooms where people sit still for long periods
    Typical riskSwitches off seated usersNuisance switching if delay is poorly setDetection beyond the room if not zoned
    Typical controlOn/offOn/off or dim, HVAC setbackHold lighting and HVAC, utilisation data

    PIR vs mmWave: Choosing the Right Detection

    PIR is proven and economical where people move. mmWave presence is the answer where people sit still. The choice is made room by room on the coverage drawing, not once for the whole building.

    PIR vs mmWave presence sensing
    FactorPIRmmWave
    PrinciplePassive infrared, reads heat movementRadar, reads micro-motion
    Still occupantsPoorStrong
    Line of sightRequiredNot strictly; can pass thin materials
    ConfigurationLens, delay, sensitivityDetection zones, distance, sensitivity
    Relative device costLowerHigher
    Where we use itCorridors, stairs, stores, washroom lobbiesBoardrooms, cabins, focus pods, video-call rooms
    Review My Sensor Layout

    Automatic Lighting Control

    Lighting is usually the first system to automate because the results are visible immediately. We design control per zone rather than per floor.

    • Occupancy on/off or dim-to-low in cabins, classrooms and meeting rooms
    • Corridor-mode: adjacent zones held at a low level for safety instead of dark
    • Scenes for presentation, cleaning and after-hours modes
    • Time schedules for common areas, with sensor override after hours
    • Manual override switches where users expect control
    • Integration with DALI-2, KNX, 0–10 V or relay-switched circuits, decided after checking existing drivers

    Daylight Harvesting

    Daylight sensors measure light at the work plane and dim fixtures near windows to hold a target lux level. It works best on glazed facades, atriums, receptions and classrooms with good windows. Success depends on zoning fixtures by distance from the glass, dimmable drivers and a lux setpoint agreed with the occupants — commissioned on site, not left at factory defaults.

    HVAC Automation with Occupancy Sensors

    Occupancy data is most valuable when it also drives air conditioning. We interface with the mechanical systems already in your building and prefer setback over hard shutdown so comfort recovers quickly.

    How occupancy data drives HVAC systems in commercial buildings
    SystemFull FormIntegration MethodOutcome
    VRV / VRFVariable Refrigerant Volume / FlowIndoor-unit controller via Modbus or dry contact from sensor relayIndoor units set back or shut down in vacant zones
    AHUAir Handling UnitBMS setpoint reset using zone occupancy countsFresh-air volume matched to actual occupancy
    FCUFan Coil UnitRoom controller / thermostat occupancy inputUnoccupied setback of 2–3 °C per room
    BMSBuilding Management SystemBACnet/IP, Modbus TCP or KNX gatewayCentral schedules, alarms, dashboards and reporting
    Lighting ControlDALI-2 / KNX / wireless meshSensor is a bus device addressed per zoneScene, dimming and daylight control per fixture group

    Automatic Washroom Sensor Solutions

    Washrooms are high-traffic, intermittently used spaces — ideal for automation.

    • Occupancy-linked lighting with cubicle-aware ultrasonic or dual-tech coverage
    • Exhaust fan interlock with run-on after the space empties
    • Sensor taps, flush valves and hand dryers where the client specifies them
    • Usage counts for housekeeping schedules, where required
    • Water-leak sensing in shafts and service areas

    Parking Sensor Automation

    Basement and multi-level parking combine lighting and guidance. We design microwave or motion-based driveway lighting with low-level holding for safety, bay-level ultrasonic detection with occupied/free indicators, level and entry count displays, and integration with CCTV and access systems where the site has them.

    Automatic Sensor Solutions for Hospitals

    Healthcare automation is not only about energy. Clinical continuity, safety, reliability, redundancy, auditability, infection-control requirements and maintainability come first. We do not make medical claims, and regulatory compliance is confirmed only for the specific project.

    Where sensors fit well

    Corridors, lift lobbies, waiting areas, staff areas, offices, washrooms, stores and parking — with occupancy lighting, exhaust interlocks and energy monitoring.

    Where manual control stays in charge

    Patient rooms, ICUs, operation theatres and critical areas use staff-controlled scenes, manual override and fail-safe behaviour. Nothing clinical depends on an automatic switch-off.

    Environmental and facility monitoring

    Temperature, humidity and air-quality sensing where applicable, HVAC monitoring, alarms to the facility team, and BMS dashboards for engineering and audit.

    Healthcare Automation Experience Across Andhra Pradesh and Telangana

    An anonymised example from LiveInSmart's published project work. Client identity is withheld; named deployments appear only with the client's approval.

    Multi-Specialty Hospital — Telangana & Andhra Pradesh — 350 Beds

    Automation and IBMS scope focused on clinical continuity and integrated facility systems.

    • Integrated building management system (IBMS)
    • Isolation-room pressure control
    • Drug-cabinet access logging
    • Nurse-call integration
    • Fire cross-trigger
    • UPS and DG load priority
    • Audit trail
    Plan Sensor Automation for My Building

    Automatic Sensor Solutions for Schools and Educational Campuses

    Campus automation should serve student comfort, the teacher's experience, safety, energy efficiency and facility visibility — in that order.

    • Classroom occupancy and daylight control tied to the timetable
    • Corridors, staircases and washrooms on motion or occupancy control
    • Libraries and laboratories with presence sensing and daylight dimming
    • Auditoriums with scenes and occupancy-based HVAC
    • Hostels with corridor lighting and after-hours schedules
    • Administrative blocks on office-style automation
    • Campus energy monitoring, and security-system integration where applicable

    Education Technology and Automation Experience

    An anonymised campus from LiveInSmart's published work. Not every element below is a sensor system — it shows our broader campus automation and integration capability.

    International School — Hyderabad — 24 Acres

    Campus-wide technology and automation delivered as one integrated scope.

    • Campus-wide access control
    • AI CCTV with student-safety analytics
    • Smart classroom AV
    • Interactive flat panels
    • Central lighting
    • HVAC scheduling by zone
    Plan Sensor Automation for My Campus

    Sensor Automation for Hospital, School and Office Chains

    Multi-site organisations get the most from a standard. We define one sensor-and-control template per space type — classroom, ward corridor, cabin, washroom, parking level — then adapt it to each building's survey. The result is consistent behaviour, common spares, one training programme and comparable dashboards across every site.

    Industry Applications

    The same engineering approach, configured to how each sector operates.

    Offices and IT Campuses

    Cabins, open floors and meeting rooms with dual-tech and presence sensing, daylight dimming on perimeters, shift-aware schedules and utilisation data for real-estate planning. See our smart office solutions.

    Hotels and Hospitality

    Guest corridors that never appear dark, back-of-house occupancy control, banquet scenes and plant-room monitoring — tuned so guest areas change smoothly rather than switch abruptly.

    Warehouses and Industrial

    High-bay microwave sensing with aisle-level zoning, low-level holding for safety, IP-rated devices for dusty areas and loading-bay lighting schedules.

    Retail and Malls

    Atrium and facade daylight dimming, back-of-house and stockroom occupancy, parking guidance and multi-outlet energy comparison.

    Government and Public Buildings

    Corridors, record rooms, offices and public halls with tamper-resistant sensors and documented commissioning for audit.

    Banks and Financial Institutions

    Branch and cabin automation with after-hours schedules and integration alongside access control and CCTV.

    Plan Sensor Automation for My Building

    BMS Integration: Sensor → Controller → BMS → Dashboard

    When sensors report into the BMS, occupancy becomes building data. The architecture we design has four layers: field sensors, zone controllers or lighting-control bus, protocol gateways (BACnet, Modbus, KNX, DALI-2) and the BMS or dashboard where facility teams see status, alarms, schedules and energy. We prepare the points list with your BMS vendor or consultant so nothing is left undefined at commissioning.

    • Zone occupancy state and runtime
    • Lighting status and dimming level
    • HVAC mode and setpoint changes
    • Environmental readings and alarms
    • Leak and fault alerts
    • Energy meters where installed

    Energy Management Without Guesswork

    We do not promise a fixed percentage saving on this page, because results depend on how your building runs today — hours, glazing, occupancy patterns and tariff. What we do: identify spaces with long unnecessary runtime during the survey, prioritise them, and where a business case is needed, meter or log a representative area before and after so savings are measured, not assumed.

    Where sensor automation typically reduces energy use — measured per building, never assumed
    Space TypePrimary SensorWhere the saving comes fromHow we verify it
    Private cabinsDual technologyLights and FCU left on in empty cabinsRuntime logs before and after
    Open-plan officeDual tech + daylightPerimeter daylight and after-hours zonesZone metering or lighting-control data
    Meeting / boardroomsmmWave presenceRooms lit and cooled between bookingsOccupancy vs runtime comparison
    Corridors & staircasesPIRFull lighting through low-traffic hoursCircuit runtime logs
    RestroomsUltrasonic / PIRContinuous lighting and exhaustRuntime and usage counts
    Basement parkingMicrowave24×7 driveway lightingCircuit metering
    Warehouse high-bayMicrowave / high-bay PIRUnused aisles fully litAisle-level runtime data

    Sensor Planning and Coverage Drawings

    Most sensor complaints are planning failures. Every LiveInSmart project gets coverage drawings on the actual floor plan showing sensor positions, detection patterns and overlap, mounting heights, zone boundaries, circuits controlled, and HVAC and BMS interfaces. Drawings are reviewed with the facility, MEP and interior teams before installation starts.

    Review My Sensor Layout

    Our 12-Step Sensor Automation Process

    One accountable team from first conversation to long-term support.

    LiveInSmart sensor automation project process
    StepStageWhat happens
    01Requirement discussionGoals, operating hours, spaces, constraints
    02Site surveyCeilings, partitions, circuits, panels, network
    03Existing-system assessmentLighting drivers, HVAC controls, BMS, access, CCTV
    04Sensor coverage designPositions, patterns, overlap, zones on the floor plan
    05Control and integration architectureControllers, gateways, protocols, points list
    06Product and protocol selectionVendor-neutral selection to suit the architecture
    07BOQ and project proposalItemised scope, phasing and AMC options
    08InstallationMounting, wiring, panel interfacing, phased if occupied
    09ProgrammingDelays, sensitivity, lux setpoints, scenes, setbacks
    10Testing and commissioningWalk tests per zone, BMS point verification
    11Facility trainingHandover, as-built drawings, override procedures
    12AMC and supportPreventive visits, re-tuning, fault attendance

    What Happens During a Site Survey

    Our engineers walk every space type, note ceiling heights and false-ceiling construction, check luminaire drivers and circuits, inspect DBs and panel space, review HVAC controllers and the BMS, check network availability, and discuss how each space is really used. You receive observations, a recommended approach and next steps for the proposal.

    Retrofit vs New Construction

    Both work. The difference is how much can be designed in rather than worked around.

    Retrofit vs new construction sensor projects
    AspectExisting building (retrofit)New build / fit-out
    CablingWireless or minimal new cablePlanned conduits and bus cabling
    Lighting driversSurvey decides if dimming drivers existSpecify DALI-2 / dimmable drivers upfront
    DisruptionNight, weekend, zone-by-zone phasingCoordinated with MEP programme
    BMSIntegrate with what existsDesign points list with the BMS consultant
    Best moment to involve usBefore any lighting replacementAt MEP design stage, before false ceiling

    Wired vs Wireless Sensor Systems

    The right answer depends on the building, not on preference.

    Wired vs wireless sensor systems
    FactorWired (DALI-2, KNX, hard-wired relay)Wireless mesh
    ReliabilityVery high, no radio dependenceHigh when the mesh is planned and surveyed
    InstallationNeeds cable routesMinimal ceiling work
    ScaleExcellent for large floor platesGood; gateway capacity must be planned
    MaintenanceNo batteries on bus devicesBattery devices need a replacement plan
    Typical fitNew builds, hospitals, campusesOccupied offices, heritage or finished interiors

    Vendor-Neutral Design, Open Protocols

    LiveInSmart does not push a single sensor brand. We select devices to fit your protocol, BMS, lighting drivers, budget and maintenance plan, and we favour open standards — BACnet, Modbus, KNX and DALI-2 — so your building is not locked to one supplier. We make no authorised-partner claims for sensor manufacturers on this page.

    Why Sensor Projects Fail Without Proper Engineering

    These are the problems we are most often called in to fix.

    • PIR installed in meeting rooms, switching off seated people
    • No coverage overlap, leaving dead zones
    • Delays left at factory defaults
    • Daylight sensors without dimmable drivers or zoning
    • HVAC and BMS never actually integrated
    • No commissioning records or training, so settings drift
    • Multiple contractors with no single point of accountability

    Project Cost: What Decides It

    We do not publish prices, ranges or per-square-foot rates, because two buildings of the same size can need very different systems. You receive an itemised proposal after the site survey.

    What decides the cost of a commercial sensor automation project
    Cost driverWhy it matters
    Number of sensorsSet by coverage drawings, ceiling height and partitions
    Sensor technologyPIR, dual-tech, mmWave and specialist sensors differ widely
    Mounting and accessCeiling height, false-ceiling type, high-bay lifts
    Controllers and relaysZones, circuits and dimming channels to switch
    Wiring or wirelessCable routes vs gateways and battery devices
    Lighting controlsWhether drivers support dimming or need replacement
    HVAC integrationVRV/VRF, AHU and FCU interface method
    BMS integrationPoints list, protocol gateways, dashboards
    NetworkingSwitches, VLANs and IT approvals where networked
    Programming and commissioningScenes, delays, lux setpoints, walk tests
    AMCPreventive visits, re-tuning and support levels
    Request Commercial Proposal

    Strong Project Experience Across Andhra Pradesh and Telangana

    LiveInSmart's installation teams work from experience centres in Hyderabad and Vijayawada, delivering commercial sensor and automation projects across Hyderabad, Vijayawada and 20+ cities in Andhra Pradesh and Telangana — spanning hospitals, campuses, offices, hospitality and building automation. **Telangana:** Hyderabad · Warangal · Karimnagar · Khammam · Nizamabad **Andhra Pradesh:** Vijayawada · Visakhapatnam · Tirupati · Rajahmundry · Kurnool

    Automatic Sensor Solutions Across India

    Sensor automation requirements differ by building type and project stage, not merely by city. A hospital in Pune and a hospital in Vijayawada need the same engineering discipline. Our experience is rooted in Andhra Pradesh and Telangana; for commercial and institutional projects elsewhere in India we can support consultation, engineering, system design and remote floor-plan review, and discuss installation coordination, commissioning and AMC case by case where operationally feasible. We do not claim a local office in cities where we do not have one.

    • Major commercial markets we receive enquiries from include Bengaluru, Chennai, Mumbai, Pune, Delhi NCR, Noida, Gurugram, Ahmedabad, Kolkata, Kochi and Coimbatore
    • Share your floor plan and building type for a remote engineering review
    • On-site scope, logistics and support model are confirmed in writing per project

    Why LiveInSmart for Commercial Sensor Automation

    One Partner. One Team. Complete Commercial Automation Solution. Most sensor projects fail not because the hardware is wrong, but because coverage, time delays and HVAC interlocks were never engineered. We own the entire chain.

    • Complete requirement analysis and site survey before any quotation
    • Sensor planning with coverage drawings, not guesswork placement
    • Building automation design across lighting, HVAC, parking and washrooms
    • Vendor-neutral product selection matched to your protocol and budget
    • In-house installation, programming and BMS integration teams
    • Testing, commissioning and documented walk-test reports
    • Annual Maintenance Contracts with on-site engineers across AP and Telangana
    • Two experience centres — Hyderabad (Ameerpet) and Vijayawada (Kanuru)
    Experience Centre · Hyderabad

    Visit our Hyderabad showroom

    Book a free demo at the LiveInSmart Hyderabad Experience Centre — listen to Dolby Atmos, see 4K laser projectors and walk through live home-automation scenes before you buy.

    Pancom Business Centre, Mumbai Hwy, Nagarjuna Nagar Colony, Ameerpet, Hyderabad 500073

    Frequently Asked Questions

    What are automatic sensor solutions?+

    Automatic sensor solutions use occupancy, motion, presence, daylight, environmental, leak and parking sensors to detect how a building is being used, and then control lighting, HVAC, washrooms, parking guidance, alarms and BMS workflows in response. The value comes from the whole chain — detection, decision, control and monitoring — not from the sensor alone.

    What is the difference between motion, occupancy and presence sensors?+

    A motion sensor reacts to walking movement and suits corridors and stairs. An occupancy sensor adds a hold-on delay and often combines two technologies, which suits general offices and classrooms. A presence sensor, usually mmWave radar, detects very small movement such as breathing, so it keeps lighting and HVAC on for people sitting still in meetings.

    Is PIR or mmWave better for offices?+

    Neither is better everywhere. PIR is economical and reliable where people walk through. mmWave presence is the right choice where people sit still — boardrooms, cabins and video-call rooms. Most office projects use both, chosen room by room on the coverage drawing.

    Can occupancy sensors control air conditioning?+

    Yes. Sensors can send an occupancy signal to VRV/VRF indoor-unit controllers, FCU thermostats or the BMS. The usual strategy is a setback of the setpoint when a zone is empty rather than a hard shutdown, so comfort recovers quickly when people return. The exact method depends on the HVAC make and controls already installed.

    How much energy will sensors save in our building?+

    It depends on how long lights and HVAC currently run in empty spaces, your operating hours, glazing and tariff. We do not quote a fixed saving before a survey. Where a client needs a business case, we can meter or log a representative area before and after, so the result is measured rather than assumed.

    Can sensors be integrated with our existing BMS?+

    Usually, yes. Integration is typically through BACnet, Modbus, KNX or DALI-2 gateways, or dry contacts for simple interlocks. The first step is reviewing your BMS make, licence, spare capacity and points list during the site survey.

    Do you work with hospitals?+

    Yes. LiveInSmart has delivered automation for a 350-bed multi-specialty hospital across Telangana and Andhra Pradesh, including IBMS, isolation-room pressure control, drug-cabinet access logging, nurse-call integration, fire cross-trigger, UPS and DG load priority and audit trail. In clinical areas we design for continuity and manual override rather than automatic switch-off.

    Are sensors safe to use in clinical areas of a hospital?+

    Sensors are well suited to corridors, waiting areas, offices, washrooms, stores and parking. Patient rooms, ICUs and operation theatres need staff-controlled scenes, manual override and fail-safe behaviour agreed with the hospital's clinical and engineering teams. We do not claim regulatory compliance unless it is verified for the specific project.

    Do you automate schools and colleges?+

    Yes. Classrooms, corridors, washrooms, libraries, labs, auditoriums and hostels are common sensor zones. Our campus experience includes a 24-acre international school in Hyderabad with access control, AI CCTV, smart classroom AV, interactive flat panels, central lighting and zone-based HVAC scheduling.

    Can one design be rolled out across a chain of hospitals, schools or offices?+

    Yes. For chains we create a standard sensor and control template per space type — classroom, ward corridor, cabin, washroom — then adapt it to each building's survey. This keeps behaviour, spares, training and dashboards consistent across sites.

    Should sensors be planned before or after the false ceiling?+

    Before. In new builds and fit-outs, sensor positions, cable routes, driver types and panel space should be fixed with the MEP and interior teams before the false ceiling closes. Existing buildings can still be retrofitted, mostly with wireless devices.

    Wired or wireless sensors — which should we choose?+

    Wired systems suit new builds, hospitals and large campuses where reliability and no batteries matter. Wireless mesh suits occupied or finished interiors where ceiling work must be minimal. We recommend one after checking ceiling access, scale and timeline on site.

    Will lights switch off while people are still in the room?+

    Not when the system is engineered correctly. That problem comes from the wrong sensor type, poor coverage overlap or a delay that is too short. We place presence sensors where people sit still, overlap coverage and set delays after walk tests.

    Do occupancy sensors record video or audio?+

    No. PIR, ultrasonic, microwave and mmWave sensors report motion or presence state, and some report anonymous counts. They do not capture images or sound. Where utilisation data is needed, we aggregate it by zone.

    Do you supply only one brand?+

    No. LiveInSmart is vendor-neutral. We select sensors, controllers and gateways to match your protocol, BMS, lighting drivers and maintenance needs, and we do not claim to be an authorised partner of any sensor manufacturer on this page.

    How is a sensor project priced?+

    We do not publish fixed prices because cost depends on the number and type of sensors, mounting, controllers, wiring, lighting drivers, HVAC and BMS integration, networking, programming, commissioning and AMC. You receive an itemised proposal after the site survey.

    Do you provide services outside Andhra Pradesh and Telangana?+

    Our installation teams are based in Hyderabad and Vijayawada. For projects elsewhere in India we can support consultation, engineering, system design and remote drawing review, and discuss on-site installation, commissioning and AMC case by case based on location and scope.

    What information should we share for a site survey?+

    Building type, city, approximate area and floors, project stage (new, fit-out or existing), existing BMS and HVAC details, the spaces you want automated, and a floor plan if available. You can share these through our contact page or WhatsApp.

    Do you provide AMC after commissioning?+

    Yes. AMC covers preventive visits, re-tuning after layout or timing changes, firmware updates where applicable, fault attendance and support for the facility team across Andhra Pradesh and Telangana.

    Can sensors help with green-building documentation?+

    Occupancy-based lighting control, daylight harvesting and metered energy data can support documentation for green-building frameworks such as IGBC and LEED. Certification itself depends on the full building submission, so we do not promise credits.